1、 HN-1220S insertion and extraction force testing machine Purpose: This machine is suitable for testing the insertion and extraction force of various connectors. Equipped with a patented automatic centering device, it can obtain completely accurate insertion and extraction force testing. It is set using the Chinese screen of Windows window, and the operation is simple and convenient, And all data can be stored (test conditions, displacement, curves, life curves, inspection reports, etc.) to solve various fixture problems in connector testing, and the male and female connectors can be automatically aligned during testing, without the problem of eating one side. Equipped with a dynamic impedance testing system, dynamic impedance can be tested and plotted while testing insertion and extraction forces.。
characteristic
1. The testing conditions of the HN-1220S insertion and extraction force testing machine are all set by the computer screen and can be stored. Select settings from the dropdown menu or directly input the numberAccording to. (Including test category, determination of movement direction, load measurement range, travel measurement range, travel origin position, travel origin detectionMeasure the speed, total number of measurements, pause time, waiting position, number of air compressions, etc.2. Capable of storing and printing graphics (load stroke curve graph load attenuation life curve graph inspection report), with overload protection function for load elementsEnsure that the load element is not damaged.3. Simultaneously display the load stroke curve and service life curve.4. Automatic load zero point detection, and the load value can be set for zero point detection.5. Load unit display: N, lb, gf, Kgf can be freely switched.6. The HN-1220S insertion and extraction force testing machine adopts a high steel structure design, paired with a Panasonic servo motor, which can ensure accuracy during long-term use and is suitable for general useTension compression test and insertion and extraction force life test.
Test items1. Connector single hole insertion and extraction test2. Connector insertion and extraction life test3. Connector Normal Force Test4. Connector row insertion and removal test5. Connector single pin and plastic retention test6. Can be connected to the contact impedance machine simultaneously (optional)7. Various compression and tensile failure strength tests.technical parameter
1. Maximum load measured: 50Kg2. Minimum decomposition capacity: 0.01Kg3. Maximum measurement height: 150mm4. Minimum fine adjustment distance: 0.01mm5. Measurement speed range: 0-300mm/min6. X-axis movement range: 0-75mm7. Y-axis movement range: 0-75mm8. Transmission mechanism: ball screw9. Drive motor: Panasonic servo motor from Japan10. Appearance size: 420 × two hundred and eighty × 960mm11. Weight: 67Kg12. Power supply: 220V/50Hz
Test report outputThe load stroke curve, life curve, and test report are all A4 standard paper specifications and printed directly by a computer printer.Insertion load stroke curve: It can directly display and store the displacement and force changes of each test.Standard configuration
1. One 1220S device2. A set of multifunctional fixtures and nipples3. One set of automatic centering device for whole row insertion and extraction4. One set of large XY mobile station5. A set of Normal Force special fixtures6. One computer integrated machine7. One manual for the HN-1220S insertion and extraction force testing machine8. One warranty certificateMain components:
Transmission mechanism: Japanese THK ball screwMotor: Panasonic servo motor from JapanLoad cell: American Translux high-precision sensorMobile platform: precision X-Y platformProximity switch: Taiwan FOTEK NPN typeButton: Japan Waquan IDECFixture: Automatic centering device single PIN holding force fixtureComputer: branded computer