Welcome to Suzhou Huanair Automation Technology Co., Ltd. website!

Chinese|English|HomepageFavoritesContact

_汽车零部件清洁度检测仪|激光平面度检测仪|全自动研磨抛光机|端子截面分析仪|全自动激光打标机|自动锁螺丝机|点胶机|全自动贴标机|三维自动影像测量仪|三维全自动影像测量仪|一键测量|手动影像测量仪

Professional automation equipment manufacturers

The industry leader in technological innovation

Free hotline

400-666-2286

Suzhou Huanair Automation Technology Co., Ltd 
Hotline: 400-666-2286
Tel: 0512-57561136
Fax: 0512-57567135
Business Mobile: 139-6262-4648
E-mail: huanair@huanair.com.cn
Address:No. 588#,Jingtan Road, Bacheng Town, Kunshan City,Jiangsu,CHina
Programmable cold and hot impact test chamber
【Product Name】Programmable cold and hot impact test chamber
【Product Category】环境检测设备
【Popular Products】649
【Updated】2023/3/20 16:00:42
Details

Programmable cold and hot impact test chamber

This cold and hot impact test chamber is divided into three box and two box types based on test requirements and testing standards. The difference lies in the test method and internal structure. The three box type is divided into a cold storage chamber and a laboratory, and the product is placed in the laboratory during testing. The two box type is divided into a high temperature chamber and a low temperature chamber, which are driven by an electric motor to achieve high and low temperature. The product is placed in the basket and moves with the basket.

Execution and compliance standards of high and low temperature impact test chambers:

1. GB/T2423.1-2001 Low temperature test method:
2. GB/T2423.2-2001 (1):
3. GB/T2423.22-1989 Temperature Change Test N:
4. National Military Standard GJB150.3-86:
5. National Military Standard GJB150.4-86:
6. National Military Standard GJB150.5-86:
7. GJB150.5-86 Temperature Impact Test:
8. GJB360.7-87 Temperature Impact Test;
9. GJB367.2-87405 Temperature Impact Test:
10. SJ/T10187-91Y73 Series Temperature Change Test Chamber - One Box:
11. SJ/T10186-91Y73 series temperature change test box - two box type:
12. Meet the standard IEC68-2-14 Test Method N Temperature Change:
10. GB/T 2424.13-2002 Test Methods - Temperature Change Test Guidelines:
11. GB/T 2423.22-2002 Temperature changes:
12. QC/T17-92 General rules for weather resistance testing of automotive components
13. EIA 364-32 Environmental impact assessment of electrical connectors and sockets for thermal shock (temperature cycling) testing program.

Programmable cold and hot impact test chamber

Introduction to Features


1: The quality advantage of the cold and hot impact testing machine is that the main core components are made from international major brands such as France Taikang, Japan's Lugong/Hequan/Mitsubishi, Schneider, America's Kuaida/DuPont Refrigerant, Denmark (DANFOSS), Sweden (AlfaLaval), and other accessories. If false, a penalty of ten will be imposed to ensure the normal and efficient operation of the high and low temperature impact testing box. Compared to other peers: using domestically produced parts or using counterfeit parts as brand accessories, shipping to customers is completely inconsistent with what is said, and the quality is greatly discounted. 2: Equipment technical advantages


1. Adopting a 7 "TFT true color LCD touch screen, it is larger, more intuitive, easy to operate, stable to operate, and more energy-efficient than other screens.
2. The evaporator adopts a water immersion leak detection method, which thoroughly checks the leak and ensures the stable operation of the equipment.
3. Adopting modular refrigeration units ensures manufacturing quality and is very convenient for maintenance and replacement.
4. Adopting a highly uniform positive pressure air duct system with high temperature uniformity.
5. Adopting the latest automatic defrosting technology to shorten the defrosting time and test the use of equipment. Efficiency has greatly increased.
6. It has multiple safety protection measures, fault alarm display, and functional display of fault causes and troubleshooting methods. 3: Energy saving advantages of the three box cold and hot impact testing machine
The three box cold and hot impact test chamber adopts a self-developed control system with high accuracy, stable and simple operation. The controller abandons the fixed mode of controllers such as Japan and South Korea, and adopts the latest fuzzy calculation technology to automatically analyze the load capacity and reasonably adjust the refrigerant flow rate, making the equipment energy-saving up to 20%.

Studio Sizemm

Outer Dimensionsmm

temperature range

box-type

350*300*500

1120*1850*1820

-60-150

two boxes

450*450*400

1220*1950*1820

500*500*400

1270*2020*1820

600*600*420

1390*2120*1820

350*350*400

1470*1420*1830

 -60-150

Three boxes

400*400*500

1520*1470*1830

500*400*500

1620*1470*1830

600*500*500

1720*1570*1830

600*500*750

1860*1860*1900


Link:Nothing
Copyright:Suzhou Huanair Automation Technology Co., Ltd.   苏 ICP 16025799  Manage   E-mail
Product:Automatic Laser Marking MachineAutomatic labeling machineAuto Parts Cleanliness TesterTerminal cross section of the analyzerLaser flatness testerAuto Parts Cleanliness TesterAutomatic three-dimensional image measuring instrument NVC432A key measureManual image measuring instrument
Business Mobile: 13962624648   Tel: 0512-57561136   Fax: 0512-57567135   Address: No. 588#,Jingtan Road, Bacheng Town, Kunshan City,Jiangsu,CHina